Assessment
Isokinetic versus functional dynamometry: which to choose
What an isokinetic machine measures, what a functional electromechanical dynamometer adds and when each one fits, with the reliability studies.
Content by MyoQuality · Updated: 2026-11-21
The isokinetic machine
An isokinetic dynamometer holds the angular velocity of a joint constant, say 60 °/s in knee extension, and measures torque in newton metres across the whole arc. The person is seated or lying down and the lever arm is aligned with the joint axis.
It is the classic reference for isolated joint strength. It gives torque-angle curves, ratios such as hamstring to quadriceps, and a highly standardised protocol.
Its limits are well known: it takes up a room, it is expensive and it tests one joint at a time, in open chain. A jump, a throw or a change of direction looks nothing like a seated knee extension.
The functional electromechanical dynamometer
A functional electromechanical dynamometer applies resistance with a motor through a cable. It measures force in newtons, linear velocity in metres per second and position, continuously.
Functional means it tests the whole movement: standing, across several joints and with the cable in whatever direction the task needs. The isokinetic mode exists, but the constant velocity is the cable’s, not a joint’s. The same device also works isometric, eccentric, inertial or with constant load.
That is why its data cannot be compared directly with an isokinetic machine. Linear force and joint torque are different quantities.
What the research says
The standing shoulder rotator test with a functional electromechanical dynamometer proved highly reliable for internal and external rotation. Concentric measures were slightly more reliable than eccentric ones and 0.6 m/s was the recommended velocity for efficiency and comfort.
For the trunk flexors, reliability was high in isometric and isokinetic modes, with coefficients of variation generally below 10 %. For the trunk rotators, a multicentre study found mean force more consistent than peak force, with the best results at 0.40 m/s.
In soccer players, eccentric hamstring force in the swing exercise showed excellent reliability, with ICCs from 0.87 to 0.91 across velocities. The authors propose it as a practical alternative to isokinetics for clubs.
When to choose each
Choose the isokinetic machine when you need joint torque by angle, comparison with published reference values in °/s, or a clinical protocol that requires it.
Choose the functional dynamometer when you want to assess and train on the same device, measure standing multi-joint movements, work across several loading modes or lack room for an isokinetic lab. MYO-M1 takes 2 × 2 m and runs from a 220 V socket.
In both cases the rule is the same: follow each person with the same device, the same position and the same velocity.